Click to see Submenus
|
Veo
Company:
Sonatest
The Veo Phased Array ultrasonic flaw detector reinforces Sonatest's reputation
for innovative technician focused product development. The veo's simple controls, superior performance, advanced features and rugged enclosure deliver simplicity, capability and reliability to the technician's finger tips.
PHASED ARRAY
Configuration 16:64 (16 pulser/receivers; driving up to 64 elements)
Transducer Socket I-PEX
Pulse Voltage -50 V to 100 V (in steps of 10 V)
Data Acquisition
Architecture Full digital delay and sum architecture
Digitizing Frequency 50/100 MHz
Digitizer Resolution 12 bits
Data Processing 16 bits samples
Data recording Full raw data recorded
Max A-Scan Length 8192 samples (32 metres in steel LW, 50MHz, 1:128)
Scan & Views
Supported Scans S-Scan & L-Scan
Real Time Views S, L, B, C-Scan, Top and End view
Colour Maps 8 Standards (Rainbow, Grayscale, Spectrum, Aeronautic or custom)
Multi Group Multiple Sector scans and TFOD
CONVENTIONAL UT/TOFD (MONO ELEMENT CHANNELS)
No. of Channels 2 TX/RX (2 multiplexed channels)
Test Mode Pulse-Echo, transmit/receive, TOFD
Receivers
Gain Range 102dB (-30dB to 72dB)
Filter Bands Narrow bands centred at 0.5 MHz, 1 MHz, 2.25 MHz 5 MHz, 10
MHz and 15 MHz; Broadband at 1 MHz to 18 MHz (-6dB)
CONVENTIONAL AND PHASED ARRAY
DAC
DAC Quantity 1 with 3 sub-DAC (per focal law in PA)
Time Corrected Gain (TCG)
Gates
A-Scan Gates 4 gates per A-scan (3 extracted A-scans per S/L-scan)
Gate Trigger Flank/Peak
S/L-Scan 2 “2D gates” per S/L-scan
Alarm LED 1 (sync on all gates & DACs)
Measurements Available in A-Scan view
1D Peak (FSH, dB, D, BPL, SD)
1D Flank (FSH, dB, D, BPL, SD)
Echo to Echo
|