NDT.org

NDT.org : Resumes : QA/QC, NDT, OCTG, welding Inspector

RF System Lab Video Borescope and Visual Testing
Posted: 7/29/2006 2:17:55 PM
Resume Header/Title:

QA/QC, NDT, OCTG, welding Inspector

Country:

Philippines

Extra Info:

I am willing to Travel.
Currently working but always looking.
I am willing to work overseas.
I prefer permanent jobs.

 Login for contact information.
 
 
 
 
 
 
Certifications:

CSWIP 3.1 level 2
Certificate No. 40282


Philippine Welding Society WELDING INSPECTOR COURSE
TESDA-NCR training certer, Gate 2 TESDA-NCR
Complex east service road, south super hiway, Taguig City
Metro manila, Philippines
Tel No. +63 02 894-4609

Eurotechnology Saudi Arabia Co. SURFACE METHOD LEVEL-2 (MT&PT)
P.O. Box 1848 Dammam 31441 K.S.A.
Tel No. (03) 815 1677 Fax (03) 841 0413

Eurotechnology Saudi Arabia Co. ULTRASONIC TESTING LEVEL-2
P.O. Box 1848 Dammam 31441 K.S.A.
Tel No. (03) 815 1677 Fax (03) 841 0413

Indusrial Support Services Co. LTD
SURFACE METHOD LEVEL-2 (MT&PT)
P.O. Box 11501 Dammam 31643 K.S.A.
Tel No. (03) 830 2200 & (03) 830 2020

Indusrial Support Services Co. LTD
ULTRASONIC TESTING LEVEL-2
P.O. Box 11501 Dammam 31643 K.S.A.
Tel No. (03) 830 2200 & (03) 830 2020

Indusrial Support Services Co. LTD
RADIOGRAPHIC TESTING LEVEL-2
P.O. Box 11501 Dammam 31643 K.S.A.
Tel No. (03) 830 2200 & (03) 830 2020

National Training Course on Non-Destructive Testing
SURFACE METHOD LEVEL-2 (MT & PT)
Philippines Nuclear Research Institute
Diliman, Quezon City, Philippines

Seminar-Workshop on Improvement of Safety
Practices in Industrial Radiography
Philippines Nuclear Research Institute
Diliman, Quezon City, Philippines

Seminar in Red Cross, Quezon Chapter
STANDARD FIRST AID &
BASIC LIFE SUPPORT COURSE
Mirant Philippines in Bay View Quezon, Philippines

Seminar in Cylinder Inspection Shell House, Makati City, Philippines

National Training Course on Non-Destructive Testing
RADIOGRAPHIC TESTING LEVEL-2
Philippines Nuclear Research Institute
Diliman, Quezon City, Philippines

National Training Course on Non-Destructive Testing
ULTRASONIC TESTING LEVEL-2
Philippines Nuclear Research Institute
Diliman, Quezon City, Philippines

Education:

UNIVERSITY OF PERPETUAL HELP rizal Rizal Bachelor of Science in Mechanical Engineering

: TECHNOLOGICAL UNIVERSITY OF THE PHILIPPINES
` Mechanical and Production Engineering Technology


SECONDARY : SAINT MICHAELS INSTITUTE

Experience:

EMPLOYER : South Seas Inspection PTE LTD. Feb. 06 to present
Azerbaijan Branch
133 Aligovsat Guliyer Street, Baku AZ1000 Azerbaijan
Tel no. +994 12 598 0771

POSITION : OCTG/NDT Inspector
Third Party Inspector

JOB DESCRIPTION:

Conduct Inspection on Drill Pipes, Drill Collars, Stabilizer and BHA as per TH Hill DS-1 category 3-5 and API 7G specs.
Conduct magnetic Particle inspection on ferrous metal (Visible and wet method) Penetrant testing for Non ferrous metal.
Conduct full drill pipe inspection as per DS-1 Cat. 3-5 (UTEA, EMI, UTG, Dimensional, MPI and Visual Inspection).
Conduct visual inspection and UT wall thickness for verifying of weight on different sizes of casing and tubing.
Conduct visual inspection on different kinds of casing and tubing connections (VAM, Hydril, Hunting Boss, ACME and Bowen connections) as per API 5CT specs.
Conduct Third Party Inspector for BP (British Petroleum) on various oilfield companies such as; Weatherford, Halliburton, Maritime Hydraulics, SDL Doelholm, Baker Hughes, Smith Services, Schlumberger and Standard Oilfield Services.
Witness Make Up Torque and hydrostatic test pressure on BP Pup joint and other assembly.
Review the quality plan submitted by the sub-contractor and check for BPs final approval.
Review of welding procedure done by sub-contractor (PQR, WPS, WPQ and WQT).
To ensure that the inspection is carried out according to BP approved quality plan.


EMPLOYER : EUROTECHNOLOGY SAUDI ARABIA Co. LTD Oct. 2003 to Nov. 2005 Gas and Oil Field Services
P.O. Box 1848 Dammam 31441 K.S.A.
Tel No. (03) 815 1677 Fax No. (03) 841 0413

POSITION : QA/QC and NDT Inspector

JOB DESCRIPTION:

To ensure that the ESACO quality system is implemented and maintained in full compliance with ISO 9001:2000 and API Q1(Sixth Edition).
To ensure that quality control plans are in place for all existing and planned products and services.
To ensure the correct application and control of the API Monogram, API 5CT-0598, API 7-0420,
API 6A-0719 and API 16A-0165
To check plans and drawing before going to fabrication
Responsible for Implementation of ESACO Route Card before and after work is done
Responsible for issuing non conformity report (NCR) in all cases when materials, items, processes or any activity affecting quality does not conform to the specified requirements drawing, specification and procedures ect.
Responsible for final inspection on manufactured piece as per drawing specification
Responsible for calibration of measuring tools like Micrometer, Bore gauge, Depth Micrometer, Caliper ect., using MIC TRAC MT-3000 (GAGE MAKER)
Witness Hydro testing as per API Specification 7 Fortieth Edition.
Conduct threads Inspection on API 5CT (Casing and Tubing), API 7 (drill Stem Items) and Premium (NKK, VAGT, VAM, Grand Prideco, and Tenaris ect.) Connection.
Oversee weld preparation and design is in accordance with the procedure and assembly at tack-up stage prior to welding.
Witness stress relief is carried out in accordance with the relevant welding procedure or specified standard
To maintain documented records at all stages of fabrication for verification and for traceability.
Conduct receiving inspection, repair and recertification of Rotary drilling connection, Casing & tubing, wellhead & Christmas tree and drilling equipment as per DS-1 specification.
Conduct Film Interpretation, Ultrasonic Thickness Gauging (UTG), Penetrant Test and Magnetic particle Inspection on well heads, Mud Cross, double studded adapter, Drill collar, Reamer, stabilizer and Drill Pipe connection ect. Based on DS-1 Inspection Procedure.
Conduct Hardness Testing on Well head & Christmas tree, tee blocks and Flanges using Telebrinell


PROJECT HANDLED:

Client : Al Masood Oil Industry Al Thuqbah K.S.A.

The Project is to conduct third party inspection and verification of Magnetic particle Inspection in critical part on the single joint elevator and string elevator, coordinate schedule and time on inspection, prepare test results and time sheet for approval.

Client : Drilling and Petroleum Services CO.
The Project is to conduct third party inspection, welding inspection and verification of Magnetic particle Inspection in critical part of mest rig pad eye, coordinate schedule and time on inspection, prepare test results and time sheet for approval.


EMPLOYER : INDUSTRIAL SUPPORT SERVICES Co. LTD May to Oct. 2003
P.O. Box 11501 Dammam 31643 K.S.A.
Tel No. (03) 830 2200 & (03) 830 2020

POSITION : QA/QC and NDT Inspector

JOB DESCRIPTION:

Assigned in Jubail as a reliever NDT Supervisor
Conduct Welding Qualification Test on welders
Supervised/Coordinate NDT technician on Petrochemia Shut Down last September 2003
Assigned NDT Technician in Jubail United Petroleum Company (JUPC) area for NDT services

ACCOMPLISHMENT:

Completed project on Petrochemia shut down and ahead of schedule.
Certified ASNT LEVEL 2 on RT, UT, MPI and PT by Mr. Ramakristan ASNT level 3
Passed Aramco level 2 Radiographic and safety examination


EMPLOYER : MAETECH CORPORATION Dec. 2002 to May 2003
A De Las Alas Drive Batangas City, Philippines
Tel No. 043 723 5824 Tele Fax 043 723 5824
Email: maetech@speedsurf.pacific.net.ph

POSITION : Assistant Radiological Health and Safety Officer (ARHSO)
Technical Supervisor/NDT Inspector


JOB DESCRIPTION:

Supervised/Conduct Radiographic Test, Ultrasonic Test, Penetrant Test and Magnetic Particles Test
A serve as the Assistant Licensees Liaison Officer recognized by the Philippine Nuclear Research Institute (PNRI) on licensing matters regarding any radioactive materials (RAM) it may possess
Prepare Test Results for Clients Representative review and approval
Assume control and institutes corrective action in emergency situation and investigate the cause of incident and determine necessary prevention action.
Develop and maintain up-to-date operating and emergency procedures
Establishes and maintains personnel monitoring program, storage facilities and leak testing program.
Establish and ensures compliance to radiation safety program.
Interpret radiographic films based on approved code by the client
Prepare Time Sheet and Payroll
Prepare Quotation, invoice and billing


PROJECT HANDLED:

Client : SIEMENS INC. January to April 2003
Sta. Rita 1000MW & San Lorenzo 500 MW
Sta. Rita, Batangas City, Philippines

The Project is to conduct Non destructive testing in the Condenser and turbine side.
I supervised and assign NDT technician for their places as per client request for testing. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used of Radioactive materials (RAM)

ACCOMPLISHMENT:

Completed project on Siemens Inc. Outage in Sta. Rita 1000 MW & San Lorenzo 500 MW and well ahead of schedule.


EMPLOYER : SUNTECH TECHNOLOGY CORPORATION Dec. 2000 V Dec. 2002
# 37 Anonas St., Project 2, Quezon City, Philippines
Tel No. 928-2011 Tele Fax (632) 928-5821

POSITION : Assistant Radiological Health and Safety Officer (ARHSO)
Technical Supervisor/NDT Inspector

JOB DESCRIPTION:

Supervised/Conduct Radiographic Test, Ultrasonic Test, Penetrant Test and Magnetic Particles Test
A serve as the Assistant Licensees Liaison Officer recognized by the Philippine Nuclear Research Institute (PNRI) on licensing matters regarding any radioactive materials (RAM) it may possess.
Prepare Test Results for Clients Representative review and approval
Assume control and institutes corrective action in emergency situation and investigate the cause of incident and determine necessary prevention action.
Develop and maintain up-to-date operating and emergency procedures
Establishes and maintains personnel monitoring program, storage facilities and leak testing program.
Establish and ensures compliance to radiation safety program.
Interpret radiographic films based on approved code by the client
Prepare Time Sheet and Payroll
Prepare Quotation, invoice and billing


PROJECT HANDLED:

Client : SIEMENS INC. October to Dec 2002
Sta. Rita 1000MW & San Lorenzo 500 MW
Sta. Rita, Batangas City, Philippines

The Project is to conduct Non destructive testing in the Condenser and turbine side.
I supervised and assign NDT technician for their places as per client request for testing. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used of Radioactive materials (RAM)

Client : MIRANT PHILIPPINES (Boiler/turbine Unit 1 Shutdown) Sept. to Nov. 2002
Sual Power Station, Sual Pangasinan, Philippines

The Project is to Supervised/conduct Non destructive testing in different part on the boiler and turbine within 25 days shut down, I assign NDT technician for their places as per client request for testing,
Review drawing and plan specially the area to be tested by ultrasonic thickness gauging inside the boiler. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used on radioactive material (RAM).

Client : MIRANT PHILIPPINES (Boiler/turbine Unit 2 Shutdown) May V July 2001
Ibabang Pulo, Pagbilao, Quezon, Philippines

The Project is to Supervised/conduct Non destructive testing in different part on the boiler and turbine within 40 days shut down, I assign NDT technician for their places as per client request for testing,
Review drawing and plan specially the area to be tested by ultrasonic thickness gauging inside the boiler. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used on radioactive material (RAM).
I handle project in SOUNTHERN ENERY QUEZON until they change their name to MIRANT Phils.

Client : SOUTHERN ENERGY QUEZON (Boiler Unit 1 Shutdown) Jan. to Feb 2001
Ibabang Pulo, Pagbilao, Quezon, Philippines

The Project is to Supervised/conduct Non destructive testing in different part on the boiler, I assign NDT technician for their places as per client request for testing, Review drawing and plan specially the area to be tested by ultrasonic thickness gauging inside the boiler. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used on radioactive material (RAM).


Client : QUEZON POWER 2000
Mauban, Quezon, Philippines

The Project is to conduct Radiographic testing in different part on the boiler as per client request for testing. Also, coordinate and monitor progress of work per day basis and prepare Test Results for Clients review and approval. Secure working permit in every used on radioactive material (RAM).

ACCOMPLISHMENT:

Completed project on Mirant Philippines both in Pagbilao and Pangasinan station and ahead of schedule.
Completed project on Siemens Inc. Sta. Rita 1000MW & San Lorenzo 500 MW and well ahead of schedule.
Completed project on Quezon Power Emergency shut down and ahead of schedule.
Attend training for National Training Course on Non-Destructive Testing Surface Method level 2 in Philippines Nuclear Research Institute